中文
 
products
NOW:HOME > PRODUCTS > HEAT EXCHANGER

PRODUCT LIST

CONTACT US

Wuxi Yiteng Pressure Vessel Co, Ltd.
Add:No 58, Zhenyang Road, Qingyang Town, Jiangyin, Jiangsu
Contacts:Mr. Zhang
Tel:13506192042
Fax:0510-86557866
Website:www.yitengrq.com
E-mail:wxzhangyaodong@163.com / yeekai@yitengrq.com

BEM Heat Exchanger

Technical Specifications of BEM Heat Exchanger
(Per TEMA Naming Convention)

The BEM Heat Exchanger is a fixed tube sheet heat exchanger under the TEMA standard. Its naming convention and core parameters are as follows:

1. TEMA Naming Convention Breakdown

BEM consists of three letters, each representing a key design feature:

  • o B: Front Head Type (B = removable channel cover for tube-side maintenance).
  • o E: Shell Type (E = single-pass standard shell).
  • o M: Rear Head Type (M = fixed tube sheet).

Example Model: BEM-600-150-4/2-1

  • o 600: Shell diameter (mm)
  • o 150: Heat transfer area (m²)
  • o 4/2: Tube-side/shell-side design pressure (MPa)
  • o 1: Number of tube passes

2. Key Technical Parameters (TEMA BEM Standard)

Parameter Typical Value/Range TEMA Requirements
Design Standard ASME VIII Div.1 + TEMA BEM Complies with TEMA Class R/C
Heat Transfer Area 5~800 m² Max 600 m² for tubes ≤9m
Design Pressure (Shell/Tube Side) 0.6~4.0 Mpa (6~40 bar) Special calculation for high-pressure models
Design Temperature -20°C to +300°C Special materials required >300°C
Shell Diameter DN150~DN1000 Reinforcement needed for shells >1m
Tube Bundle Parameters
- Tube OD Φ19.05 mm (3/4") / Φ25.4 mm (1") TEMA-recommended sizes
- Tube Length 1.5m / 3m / 6m / 9m Length-to-diameter ratio ≤8:1
- Tube Layout Angle 30° / 45° / 90° Triangular or square pitch
Tube Sheet Thickness 50~200 mm Calculated based on pressure and diameter
Baffle Type Single segmental (20%~35% cut) Baffle spacing ≥1/5 shell diameter
Nozzle Flanges ANSI 150~600 / DIN PN10~40 Flange spacing ≥1.2×tube OD

3. Key Structural Features

1.Fixed Tube Sheet Design (M-Type):

  • o Tube bundle welded to the shell, simple structure with high pressure resistance.
  • o Suitable for clean shell-side fluids or chemically cleanable applications.

2.Removable Front Channel Cover (B-Type):

  • o Bolted cover allows tube-side maintenance and individual tube replacement.

3.Single-Pass Shell (E-Type):

  • o Standard shell design with optimized baffle arrangement.

4. Typical Applications

  • o Chemical Processes: Heat exchange for clean media (e.g., circulating water, solvents).
  • o HVAC Systems: Chillers, district heating systems.
  • o Food/Pharma: Heating/cooling of low-viscosity fluids.
  • o Power Industry: Low-pressure feedwater heaters.

5. Selection Limitations & Notes

1.Thermal Expansion Limitation:

  • o Use with caution if shell-tube ΔT >50°C (risk of thermal stress cracking).

2.Cleaning Limitations:

  • o Shell side cannot be mechanically cleaned; only for clean or chemically cleanable fluids.

3.Pressure Limitation:

  • o Design pressure typically ≤4.0 Mpa; higher pressures require thicker tube sheets.

6. Comparison with Other TEMA Types

Model Front Head Shell Type Rear Head Best For
BEM Removable (B) Single-pass (E) Fixed tube sheet (M) Clean fluids + small ΔT
AES Removable (A) Single-pass (E) Packed floating head (S) High-pressure + cleanable
BEU Removable (B) Single-pass (E) U-tube bundle (U) Large ΔT + low maintenance
Note: BEM exchangers are low-cost and simple but require strict operating conditions (clean media + small ΔT).

COPYRIGHT © 2021 Wuxi Yiteng Pressure Vessel Co, Ltd.