BEM Heat Exchanger
The BEM Heat Exchanger is a fixed tube sheet heat exchanger under the TEMA standard. Its naming convention and core parameters are as follows:
BEM consists of three letters, each representing a key design feature:
Example Model: BEM-600-150-4/2-1
| Parameter | Typical Value/Range | TEMA Requirements |
|---|---|---|
| Design Standard | ASME VIII Div.1 + TEMA BEM | Complies with TEMA Class R/C |
| Heat Transfer Area | 5~800 m² | Max 600 m² for tubes ≤9m |
| Design Pressure (Shell/Tube Side) | 0.6~4.0 Mpa (6~40 bar) | Special calculation for high-pressure models |
| Design Temperature | -20°C to +300°C | Special materials required >300°C |
| Shell Diameter | DN150~DN1000 | Reinforcement needed for shells >1m |
| Tube Bundle Parameters | ||
| - Tube OD | Φ19.05 mm (3/4") / Φ25.4 mm (1") | TEMA-recommended sizes |
| - Tube Length | 1.5m / 3m / 6m / 9m | Length-to-diameter ratio ≤8:1 |
| - Tube Layout Angle | 30° / 45° / 90° | Triangular or square pitch |
| Tube Sheet Thickness | 50~200 mm | Calculated based on pressure and diameter |
| Baffle Type | Single segmental (20%~35% cut) | Baffle spacing ≥1/5 shell diameter |
| Nozzle Flanges | ANSI 150~600 / DIN PN10~40 | Flange spacing ≥1.2×tube OD |
Fixed Tube Sheet Design (M-Type)
Removable Front Channel Cover (B-Type)
Single-Pass Shell (E-Type)
Thermal Expansion Limitation
Cleaning Limitations
Pressure Limitation
| Model | Front Head | Shell Type | Rear Head | Best For |
|---|---|---|---|---|
| BEM | Removable (B) | Single-pass (E) | Fixed tube sheet (M) | Clean fluids + small ΔT |
| AES | Removable (A) | Single-pass (E) | Packed floating head (S) | High-pressure + cleanable |
| BEU | Removable (B) | Single-pass (E) | U-tube bundle (U) | Large ΔT + low maintenance |
ABOUT YITENG
PRODUCTS
CONTACT US
Wuxi Yiteng Pressure Vessel Co, Ltd.